Third-Party Fixtures - ETC F-Drive R12 Series Installation Manual

Hide thumbs Also See for F-Drive R12 Series:
Table of Contents

Advertisement

Connect ArcSystem Pro One-Cell Luminaires to the Terminal Block
Output
The CC-150 Card can support four ArcSystem Pro One-Cell, Pro One-Cell Small, or Pro One-Cell
Micro luminaires using its terminal block output, with two pins per luminaire.
The F-Drive R12 ships with twelve eight-pin connectors (ETC part number 7148K1016). Refer to
the
Terminal Block Pinout on page 26
Note:
their input cables. See the table below for wire colors.

Third-Party Fixtures

The CC-150 Card and the CV-150 Card support a wide variety of third-party loads. Determining
compatibility between these loads and the driver is an important step toward ensuring the
success of a project. Search the
etcconnect.com/compatibility
compatibility database, follow the instructions at the link above to contact the ETC Applications
Engineering department to arrange for compatibility testing.
Third-Party constant current or constant voltage fixtures can be connected to a CC-150 Card or
CV-150 Card either directly to the eight-pin terminal block on the output card or to the RJ45
output of the card through a B-Box4 breakout box with terminal outputs (FD-BBOX-4T) that
provides four two-pin terminals.
CAUTION:
the third-party load.
Connect Lighting by Other Manufacturers to the RJ45 Output with
B-Box4
The FD-BBOX-4T takes a single four-channel RJ45 output from an FTW-150 Card or CC-150 Card
and provides four separated two-pin output channels. Visit the F-Drive System Design Tool at
etcconnect.com/Products/Power-Controls/LED-Drivers/F-Drive/F-Drive-System-Design-
Tool.aspx and see the F-Drive B-Box4 Installation Manual and the F-Drive R12 and W1 Wiring
Reference Guide for more information.
Connect Lighting by Other Manufacturers to the Terminal Block
Output
The F-Drive R12 ships with twelve eight-pin connectors (ETC part number 7148K1016). Refer to
the
Terminal Block Pinout on page 26
28
ArcSystem Pro One-Cell luminaires have different wire color conventions on
Luminaire
ArcSystem Pro One-Cell (standard) negative (-) positive (+)
ArcSystem Pro One-Cell Small
ArcSystem Pro One-Cell Micro
LED Dimming Compatibility Database
to see if your load is compatible. If your load is not in the
Do not exceed any Class 2 limits stated by the manufacturer of
.
Wire Color and Polarity
Red
negative (-) positive (+)
positive (+) negative (-)
Black
at
R12 Installation Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

R12 series