4. Press EXIT to return to the Diagnosis menu.
DIAGNOSIS
ERRORS

VOLTAGES

TEMPERATURES

FAN SPEEDS

VERSIONS
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 8-29
8.9.3
Voltages
How to show the voltages
1. Push the cursor key ↑ or ↓ to highlight Voltages. (menu 8-31)
2. Press ENTER to select.
The Voltages overview window will be displayed. (menu 8-32)
3. Use the ↑ or ↓ keys to scroll through the list of displayed voltages.
4. Press EXIT to return to the Diagnosis menu.
DIAGNOSIS
ERRORS
VOLTAGES
TEMPERATURES
FAN SPEEDS
VERSIONS
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 8-31
8.9.4
Temperatures
How to show the temperatures
1. Push the cursor key ↑ or ↓ to highlight Temperatures. (menu 8-33)
2. Press ENTER to select.
The Temperatures overview window will be displayed. (menu 8-34)
3. Use the ↑ or ↓ keys to scroll through the list of displayed temperatures.
4. Press EXIT to return to the Diagnosis menu.
DIAGNOSIS
ERRORS
VOLTAGES
TEMPERATURES
FAN SPEEDS
VERSIONS
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 8-33
8.9.5
Fan speeds
How to show the temperatures
1. Push the cursor key ↑ or ↓ to highlight Fan speeds. (menu 8-35)
R5976690 XLM H25 03/09/2004
ERRORS :
Temp Elcabox low
Select with ↑ or ↓
<EXIT> to return
Menu 8-30
VOLTAGES
Tec
12.00V
Fan3
23.75V
Fan2
23.50V
Fan1
23.15V
Fan0
23.12V
+5V
5.00V
+3.3V
3.25V
+24V
23.75V
+12V ASCAR2 12.00V
Select with ↑ or ↓
<EXIT> to return
Menu 8-32
TEMPERATURES
Rack
0
Lamp house
34
Heats. SMPS 2S 51
Heats. SMPS 2P 53
Heats. SMPS 1S 52
Heats. SMPS 1P 50
Heats. PFC
92
Elco box
0
DMD Red
30
DMD Green
53
DMD Blue
31
Select with ↑ or ↓
<EXIT> to return
Menu 8-34