Or,
enter the digits directly with the numeric keys.
SERVICE
IDENTIFICATION
CHANGE PROJECTOR ADDRESS
COMMUNICATION
DATE AND TIME
LAMP
DIMMING/CLO
CONVERGENCE
BROADCAST MODE [OFF]
DIAGNOSIS
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 8-7
8.4
Communication
Overview
•
Baud rate Setting
•
Serial Interface setting
•
RS422 Termination
•
Network Configuration
8.4.1
Baud rate Setting
How to setup
1. Push the cursor key ↑ or ↓ to highlight Communication. (menu 8-9)
2. Press ENTER to select.
The communication menu will be displayed. (menu 8-10)
3. Push the cursor key ↑ or ↓ to highlight Baudrate.
4. Press ENTER to toggle between the available baudrates.
SERVICE
IDENTIFICATION
CHANGE PROJECTOR ADDRESS
COMMUNICATION
DATE AND TIME
LAMP
DIMMING/CLO
CONVERGENCE
BROADCAST MODE [OFF]
DIAGNOSIS
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 8-9
Available baud rates
115200/57600/38400/19200/9600/4800/1200
8.4.2
Serial Interface setting
Set up
1. Push the cursor key ↑ or ↓ to highlight Communication. (menu 8-11)
2. Press ENTER to select.
The communication menu will be displayed. (menu 8-12)
3. Push the cursor key ↑ or ↓ to highlight RS232/RS422.
R59770014 XLM HD30 07/07/2006
CHANGE PROJ. ADDRESS
PROJECTOR ADDRESS 1
COMMON ADDRESS 0
Select with ↑ or ↓
Reprogram with ←,→
<ENTER> to confirm
<EXIT> to return
Menu 8-8
COMMUNICATION
BAUDRATE [115200]
INTERFACE STANDARD[RS232]
RS422 TERMINATION [OFF]
NETWORK
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 8-10
8. Service
101