Power-Up Diagnostics

An LED test is performed each time the drive is powered up. The initial boot sequence
can take several seconds. After the LEDs complete the diagnostic LED sequence, the
option is successfully initialized. The LEDs then assume operational conditions as shown
in
Table
4.3.
Sequence
1
2
3
16
Indication
Color
Display
Green
Flashing
Red
ON
Red
Flashing (1)
Red
Flashing (2)
Red
Flashing (3)
Yellow
OFF
Yellow
ON
Green
OFF
Green
ON
Green
Flashing
Table 4.3 Power-Up Diagnostic LED Sequence
Module Status (MS)
Green
Red
Green
Operating State
Connected and stopped
bUS fault
Lost communication
Lost link
IP address settings bad
10 Mbps is established
100 Mbps is established
Link is not established
Link is established
Link is established and
there is network activity
Network Status (NS)
OFF
OFF
OFF
YASKAWA TOEP C730600 89B PROFINET Installation Manual
Description
Connection established
with I/O controller and in
STOP mode.
Unrecoverable bUS fault.
Host communication is
temporarily lost.
No link detected to
network.
Use the operator or
DriveWizard to check and
change F7 parameters,
then cycle power. You can
also set the PLC to assign
the IP address.
This will clear the fault
automatically.
-
Time (ms)
250
250
-