Adjust the levelling legs of the appliance. Acceptable is the tilt angle 1° rearward.
If equipment tilts other than back- wards,
this will cause condensates to deposit in
the tank.
WARNING
4.4

AIR INLET/OUTLET INSTALLATION

As the AQUA HP absorbs heat during its operation, the air flow (inlet/out- let) must be directed
to unheated areas. The equipment will cool the room where it is placed and so if it is installed
in heater rooms, the air flow must be directed to other rooms and/or the outside.

4.4.1 Installation without Ducts

The AQUA HP equipment must be in- stalled in a
place that is not too heated, and may be used for
dehumidifying and cooling these rooms (e.g.,
laundries, cellars, etc). Distance between the top
of the unit and the ceiling must be no less than
600 mm.
If the distance between the unit and the ceiling
is less than 600mm, two elbow-type joints must be
installed as shown in the following picture.
- 13 -