We recommend that the hot water distribution from the heater was as short as possible
to minimise heat losses.
Heaters TO/E UP must be provided with a discharge valve mounted on the cold service water
inlet to the heater for potential disassembly or repair.
When assembling the security equipment, follow the standard.

8 ELECTRIC INSTALLATION

The wiring diagram is attached in the manual to the water heater (Figure 4). The heater must be connected
via a separate supply with a front-end main switch. The heater is connected to 230V/50Hz electric network
by a wire with a plug into the socket. The electric installation must comply with the applicable electrical
standards. The connection of the heater to the electric network must be made after the water heater
is installed and the heater is filled with water.
Follow the rules of protection against electric shock in accordance with the ČSN 33 2000-4-41 standard.
The degree of protection of electric parts of the heater is IP X5.

9 HEATER COMMISSIONING

After connecting the heater to the water supply network, the heater can be put into operation. Before
opening the power supply, the tank must be filled with water. The process of first heating must be executed
by licensed professional who has to check it. Both the hot water outlet pipe and safety armature parts may
be hot.
Procedure:
a)
check the electric and water main installation
b)
open the hot water valve on the combination faucet
c)
open the cold water inlet valve to the heater
d)
as soon as the water starts running through the hot water valve, the heater is filled and the valve
closes
e)
using the front-end main switch open electricity and thus the heater activates
Before first use, or after longer periods, it is necessary to ensure flushing, irrigation
and ventilation heater before starting the heating. The first heating tank must be monitored.
- 9 -