Project Setup; Requirements; Hardware; Table 3-1: Development Tools Required By Profinet Device Stack - Renesas RZ Series Quick Start Manual

Hide thumbs Also See for RZ Series:
Table of Contents

Advertisement

RZ/N1D/S/L Group
Application Note
PROFINET Quick Start Guide

3 Project Setup

The following chapter describes the setup and usage of the PROFINET device stack.

3.1 Requirements

Please extract the released archive to your workspace and make sure that the following components
are installed:
Tool
IAR Embedded Workbench for ARM
IAR C/C++ Compiler for ARM
GCC

Table 3-1: Development Tools required by PROFINET device stack

If you need logging, a terminal emulator like putty should be also installed and configured to the correct
USB serial interface of the RZ/N1 board. If no messages appear after the board is started than another
serial port (from the 4 installed devices) must be tried.

3.2 Hardware

Please take care to follow the setup guidelines for the RZ/N1 Demo Board from the Linux and U-boot
documentation - RZN1x-Quick-Start-Guide.pdf
Please follow these initial steps to setup the UART and DFU connection.
1. Connect the board to a PC via the UART and the DFU interface. After the driver for the device
has been installed, additional serial ports will show up.
a. On Linux PCs, if you have no other serial-over-USB devices attached, this is
/dev/ttyUSB2.
b. On Windows PCs, open the device manager and look up for new USB Serial Ports on
section ports. The RZ/N1D and RZ/N1S board uses the 3
2. Open suitable terminal emulator on PC:
a. On Linux PCs, open a serial terminal e.g. with
cu -e -o -115200 -l /dev/XXX
Replace the "XXX" with the serial device where the UART of the board is connected to.
b. On Windows PCs, open a serial terminal program e.g. PuTTY and select the COM port
where the UART is connected to. The following settings must be configured for the
connection:
R11QS0010ED0143 Rev.1.4.3
July 09, 2019
Preliminary document. Specifications in this
document are tentative and subject to change.
Version
8.32.3.20228
8.32.3.193
8.2.0
rd
of the 4 COM ports.
3. Project Setup
Page 8 of 26

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rz/n1 seriesRz/n1dRz/n1sRz/n1l

Table of Contents