a. Compile the project via "Project/Compile" or "Project/Rebuild all".
b. Press and hold the devices software-reset button.
c. Click on "Download and Debug" and release the software-reset button as soon as the
"Busy" window opens.
9. Follow these steps for the Debug-ROM configuration
a. Click on "Download and Debug".
b. Set reset mode to "Hardware" and press "Make & Restart Debugger".
c. Check, if the reset mode is still on "Hardware". If not, repeat the previous step.

Figure 3-5: Changing Reset mode of RZ/N1L in Debug-ROM configuration

After the Debug view opened, click on the "Go" button.
3.5.3 Core To Core variant – RZ/N1D (Communication Core)
The binary file for the CM3 core is located at the board type related IAR Embedded Workbench folder
goal\projects\goal_pnio_rpc\00_goal_rpc\ respectively
goal\projects\goal_pnio_rpc\00_goal_rpc_demo\.
Load the binary file to the flash according to the following steps.
1. Connect a Linux PC to the board according to section 3.2.
2. Power up the board.
3. Open a serial terminal according to section 3.2.
4. Hit any key to stop the autoboot of the U-Boot
5. Type "dfu" in the serial terminal of the board and hit enter.
R11QS0010ED0143 Rev.1.4.3
July 09, 2019
Preliminary document. Specifications in this
document are tentative and subject to change.

Figure 3-4: IAR Workbench "Busy"-Window

3. Project Setup
Page 13 of 26

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rz/n1 seriesRz/n1dRz/n1sRz/n1l

Table of Contents