Adjustment and Troubleshooting
15) Blank Page Print out (1)
Description: Blank page is printed.
1. Bad ground contacts in
OPC and/or toner cartridge.
Service Manual
4-40
All manuals and user guides at all-guides.com
1. Check if the Ground-OPC or the
OPC Ground Zener diode are
defective or open circuit.
(set inside left side)
2. Remove contamination of the
terminals on the toner cartridge
and the unit.