Service and Maintenance

The Vortek NXT hoist can only be serviced by an ETC trained/authorized person.
Note:
WARNING:

11.1 General Checks

Before each use, check for proper operation of the hoist and QTC-1 Field Service Kit.
1:
Turn on power to the hoist. See
2:
Turn on power to the QT1-C Field Service Kit. After power up, verify "System OK" appears on
the LCD. See
3:
Operate the hoist to the full lower and upper limits. Hoist operation must stop when a limit is
reached. See
4:
While operating the hoist, pay close attention to any unusual operating noises.
5:
While operating the hoist, press the E-stop button. Hoist operation must stop immediately. See
8.4 Testing and Resetting E-stop System
6:
With the hoist in the lowered position, inspect all batten terminations for wear and damage.
47
Records of Standard Inspection and Maintenance Check List must be kept by the
owner and must be signed and dated by the person carrying out the inspections and
maintenance.
While performing general checks, annual inspection and maintenance,
including E-stop testing, make certain the entire location beneath the batten
is closed off and all persons, including the operator, are away from the load.