Monitor The Power Supply; Turn On; Turn On The Module - Quectel RM510Q-GL Hardware Design

Hide thumbs Also See for RM510Q-GL:
Table of Contents

Advertisement

NOTE
To avoid damages to the internal flash, please cut off power supply after the module is turned off by
pulling down FULL_CARD_POWER_OFF# pin for more than 7 s, and DON'T cut off power supply directly
when the module is working.

3.3.3. Monitor the Power Supply

AT+CBC command can be used to monitor the voltage value of VCC. For more details, see
document [4]

3.4. Turn on

3.4.1. Turn on the Module

FULL_CARD_POWER_OFF# (FCPO#) is used to turn on/off the module. When the input signal is
asserted high ( ≥ 1.19 V), the module will turn on. When the input signal is driven low signal ( ≤ 0.2 V) or
tri-stated, the module will turn off.
This input signal is 3.3 V tolerant and can be driven by either 1.8 V or 3.3 V GPIO. Also, it has internally
pulled down with a 100 kΩ resistor.
Table 8: Definition of FULL_CARD_POWER_OFF#
Pin
Pin Name
No.
FULL_CARD_
6
POWER_OFF#
It is recommended to use a host GPIO to control FULL_CARD_POWER_OFF#. A simple reference circuit
is illustrated in the following figure.
RM510Q-GL_Hardware_Design
I/O
Description
Turn on/off the
module.
DI, PD
High level: Turn on
Low level: Turn off
RM510Q-GL Hardware Design
DC
Comment
Characteristics
V
max = 4.4 V
IH
Pull down with a
V
min = 1.19 V
IH
100 kΩ resistor.
V
max = 0.2 V
IL
5G Module Series
30 / 88

Advertisement

Table of Contents
loading

Table of Contents