Dimensional Data

Table 7-4. Dimensional Data
Machine Length (stowed)
Up and Over Platform Height
Horizontal Reach @ Maximum Up and
Over
Machine Width
Wheel Base
Working Height
Platform Height
Track Width
Tail Swing (Any Position)
Ground Clearance
31215012
SECTION 7 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE

Hydraulic Oil

21 ft. 2 in. (6.45 m)
25 ft. 3 in. (7.7 m)
23 ft. 9 in. (7.24 m)
5 ft. 9 in. (1.75 m)
6 ft. 7.0 in. (2.00 m)
51 ft. 0 in. (15.54 m)
NOTE:
45 ft. 0 in. (13.72 m)
5 ft. 0 in. (1.51 m)
0
8 in. (0.20 m)
Table 7-5. Hydraulic Oil
Hydraulic System
Operating
Temperature Range
+0° to + 180° F
(-18° to +83° C)
+0° to + 210° F
(-18° to +99° C)
+50° to + 210° F
(+10° to +99° C
Hydraulic oils must have anti-wear qualities at least to API Ser-
vice Classification GL-3, and sufficient chemical stability for
mobile hydraulic system service.
Aside from JLG recommendations, it is not advisable to mix oils
of different brands or types, as they may not contain the same
required additives or be of comparable viscosities. If use of
hydraulic oil other than standard UTTO is desired, contact JLG
Industries for proper recommendations.
S.A.E. Viscosity
Grade
10W
10W-20, 10W30
20W-20