Pilz PIT si1.1 Operating Manual

Pilz PIT si1.1 Operating Manual

Control and signal devices
Hide thumbs Also See for PIT si1.1:

Advertisement

Quick Links

PIT si1.1
Control and signal devices
Operating Manual­21040­EN­03

Advertisement

Table of Contents
loading

Summary of Contents for Pilz PIT si1.1

  • Page 1 PIT si1.1 Control and signal devices Operating Manual­21040­EN­03...
  • Page 2 Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received. Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®, SafetyEYE®, SafetyNET p®, the spirit of safety® are registered and protected trademarks of Pilz GmbH & Co. KG in some countries.  SD means Secure Digital...
  • Page 3: Table Of Contents

    Content Introduction Validity of documentation Using the documentation Definition of symbols Safety Intended use Safety regulations Use of qualified personnel Warranty and liability Disposal Unit features Function description Installation and wiring Wiring Installation Connection examples Driven via PNOZmulti Driven via PSSuniversal Dimensions Technical details Order reference EC declaration of conformity Operating Manual PIT si1.1 21040­EN­03...
  • Page 4: Introduction

    PIT si1.1 Introduction Validity of documentation This documentation is valid for the product PIT si1.1. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product. Using the documentation This document is intended for instruction. Only install and commission the product if you have read and understood this document. The document should be retained for future ref­ erence. Definition of symbols Information that is particularly important is identified as follows: DANGER! This warning must be heeded! It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that can be taken. WARNING! This warning must be heeded! It warns of a hazardous situation that could lead to serious injury and death and indicates preventive measures that can be taken. CAUTION! This refers to a hazard that can lead to a less serious or minor injury plus material damage, and also provides information on preventive measures that can be taken. NOTICE This describes a situation in which the product or devices could be dam­ aged and also provides information on preventive measures that can be taken. It also highlights areas within the text that are of particular import­ ance. Operating Manual PIT si1.1 21040­EN­03...
  • Page 5: Safety

    PIT si1.1 INFORMATION This gives advice on applications and provides information on special fea­ tures. Safety Intended use The muting lamp is intended for use as an indicator in muting operation. CAUTION! The muting lamp is not monitored. In safety­related applications, its function must be monitored using appropriate means. The following is deemed improper use in particular: Any component, technical or electrical modification to the product Use of the product outside the areas described in this manual Use of the product outside the technical details (see chapter entitled "Technical De­ tails"). Safety regulations Use of qualified personnel The products may only be assembled, installed, programmed, commissioned, operated, maintained and decommissioned by competent persons. A competent person is someone who, because of their training, experience and current pro­ fessional activity, has the specialist knowledge required to test, assess and operate the work equipment, devices, systems, plant and machinery in accordance with the general standards and guidelines for safety technology. It is the company’s responsibility only to employ personnel who: Are familiar with the basic regulations concerning health and safety / accident preven­ tion Have read and understood the information provided in this description under "Safety" And have a good knowledge of the generic and specialist standards applicable to the specific application. Operating Manual PIT si1.1 21040­EN­03...
  • Page 6: Warranty And Liability

    PIT si1.1 Warranty and liability All claims to warranty and liability will be rendered invalid if The product was used contrary to the purpose for which it is intended Damage can be attributed to not having followed the guidelines in the manual Operating personnel are not suitably qualified Any type of modification has been made (e.g. exchanging components on the PCB boards, soldering work etc.). Disposal When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Unit features Signal lamp for muting operation Scope of supply: – Muting lamp including bulb – mounting bracket – 2 screws Function description In muting mode, the operator must be made aware of the hazard that results from the sus­ pension of the safety function. The muting lamp is designed for this purpose. It illuminates as soon as muting mode is started. Installation and wiring The cover must be taken off and the bulb removed for installation and wiring: Turn the cover to the right and pull it off upwards. While applying slight downward pressure, rotate the bulb by approx. 90° to the right and pull it out. Fig.: Take off the cover and remove the bulb Operating Manual PIT si1.1 21040­EN­03...
  • Page 7: Wiring

    PIT si1.1 Wiring CAUTION! Wire the lamp when it is isolated from the power supply. Perforate the stuffing box using a screwdriver. The power supply is fastened underneath the bulb holder with the aid of the two screw terminals. Press the terminals beside lamp holder to the side and push the wire into the cut­outs above the holder. 2 cores Fig.: Wiring Installation Install the base directly on a horizontal surface or on the fastening bracket using the two screws supplied. Install the fastening bracket with the base on a vertical surface. Fig.: Installation Operating Manual PIT si1.1 21040­EN­03...
  • Page 8 PIT si1.1 Refit the bulb and the cover. To ensure that no dirt enters the housing, the cover must be securely locked to the base. Rotate the cover to the left until the lug on the cover en­ gages behind the lug on the base. Fig.: Fit the bulb and lock the cover If it is necessary to open the cover again, e.g. to replace the bulb, press down the strip un­ derneath the lug using a screwdriver. In this way the cover is unlocked and can be opened by rotating. Fig.: Re­open cover Operating Manual PIT si1.1 21040­EN­03...
  • Page 9: Connection Examples

    PIT si1.1 Connection examples Application examples for use with the PMUT X1P muting controller are described in the re­ lated operating manual. Driven via PNOZmulti PIT si1.1 24VDC Monitoring lamp current Monitoring open circuit /1.a.5 /1.a.5 CHIP-Card POWER FAULT PNOZ m1p PNOZ mo3p Fig.: Driven via PNOZ m1p with PNOZ mo3p Operating Manual PIT si1.1 21040­EN­03...
  • Page 10: Driven Via Pssuniversal

    312 010 312 190 312 220 SB ADDRESS SafetyBUS p PSSu BS PSSu BP 1/8S 1/8S +24V Periph.Supply PIT si1.1 0V Periph.Supply 24VDC Monitoring lamp current +24V Module Supply Monitoring open circuit 0V Module Supply C-rail supply Fig.: Driven via PSSu H SB with PSSu E F PS and PSSu E F DI OZ 2 Operating Manual PIT si1.1 21040­EN­03...
  • Page 11: Dimensions

    PIT si1.1 Dimensions Fig.: Dimensions Technical details General Approvals CE, cULus Listed Self­monitored Lamp bulb Kind Type BA15d, 24 V DC, 5W Electrical life 1,000 hours Electrical data Supply voltage 24,0 V Voltage Kind Voltage tolerance ­15 %/+15 % Output of external power supply (DC) 5,0 W 100 % Continuous duty Environmental data Ambient temperature Temperature range ­25 ­ 50 °C Storage temperature Temperature range ­25 ­ 50 °C Protection type IP65 Housing Mechanical data Cable diameter 5 ­ 8 mm Cable gland ISO 20 mm Mounting position Material...
  • Page 12: Order Reference

    PIT si1.1 Mechanical data Dimensions Height 138,5 mm Diameter of pushbutton 100,0 mm Weight 255 g Order reference Product type Features Order no. PIT si1.1 muting lamp Signal lamp for muting operation 620 010 EC declaration of conformity This product/these products meet the requirements of the directive 2004/108/EC for ma­ chinery of the European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix­Wankel­Str. 2, 73760 Ost­ fildern, Germany Operating Manual PIT si1.1 21040­EN­03...
  • Page 13 Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95446300 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 Switzerland +1 888-315-PILZ (315-7459) Austria +43 1 7986263-0 +41 62 88979-30 Mexico...

This manual is also suitable for:

620010