Pilz PSSu K S RS232 Modbus ASCII Operating Manual
Pilz PSSu K S RS232 Modbus ASCII Operating Manual

Pilz PSSu K S RS232 Modbus ASCII Operating Manual

Decentralised system pssuniversal i/o
Hide thumbs Also See for PSSu K S RS232 Modbus ASCII:

Advertisement

Quick Links

PSSu K S RS232 Modbus ASCII
Decentralised system PSSuniversal I/O
}
Operating Manual 1001689-EN-05

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSSu K S RS232 Modbus ASCII and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pilz PSSu K S RS232 Modbus ASCII

  • Page 1 PSSu K S RS232 Modbus ASCII Decentralised system PSSuniversal I/O Operating Manual 1001689-EN-05...
  • Page 2 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
  • Page 3: Table Of Contents

    Section 6 Wiring Interface configuration 6.1.1 RS232 interface Section 7 Operation Messages Display elements 7.2.1 Display element for operational readiness 7.2.2 Display element for module error 7.2.3 Display elements for data transmission Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 4 Contents Section 8 Technical details Section 9 Order reference Product Accessories Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 5: Introduction

    Introduction Introduction Validity of documentation This documentation is valid for the product PSSu K S RS232 Modbus ASCII. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 6: Definition Of Symbols

    It also highlights areas within the text that are of particular import- ance. INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 7: Overview

    Max. number per system: 6 Data exchange based on the Modbus ASCII protocol LEDs for: – Operational readiness – Module error – Data transmission For standard applications in system environment B (automation system PSS 4000) Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 8: Front View

    – 2D code – Order Number – Serial Number – Hardware version number 2: Name of compact module 3: D-Sub connector (male) X1 4: LEDs for status display and module diagnostics Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 9: Safety

    Any use of the module that is not in accordance with the technical details. INFORMATION The module is supported by PAS4000 from version 1.0.0. We recommend that you always use the latest version (download from www.pilz.de). Safety regulations 3.2.1 Use of qualified personnel The products may only be assembled, installed, programmed, commissioned, operated, maintained and decommissioned by competent persons.
  • Page 10: Warranty And Liability

    In safety-related applications, please comply with the mission time T in the safety-re- lated characteristic data. When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 11: Function Description

    All the configuration data is stored in the head module and is assigned to the module on restart. This way the configuration data is retained even if you change the module. Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 12: Integrated Protection Mechanisms

    The module has the following configuration options: Interface parameter Threshold receive buffer 4.4.1 Interface parameters The following interface parameters can be configured: Transmission rate Xon/Xoff when sending Xon/Xoff when receiving RTS and CTS enabled Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 13: Receive Buffer Threshold

    Receive buffer threshold The number of Bytes in a receive buffer of the module is defined with this value, from which the status bit "Receive buffer full" is set (default value: 512). Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 14: Installation

    Electrostatic discharge can damage components. Ensure against discharge before touching the product, e.g. by touching an earthed, conductive sur- face or by wearing an earthed armband. 5.1.1 Dimensions Schematic representation: 30 mm 49,2 mm 1,18" 1,94" Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 15: Install Compact Module

    – On the mounting rail, carefully slide the compact module to the left, in parallel to the adjoining module, until you hear the lateral mounting hooks on the adjacent module lock into position [4]. Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 16 Installation Schematic representation: Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 17: Wiring

    D-Sub male connector 1: n.c. 2: Input Rx (receive data) 3: Output Tx (send data) 4: n.c. 5: GND 6: n.c. 7: Output RTS 8: Input CTS 9: n.c. n.c. = not connected Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 18: Operation

    The module has an LED for displaying that the system is ready for operation (LED "Run"). Description Colour Status - - - Module not ready for oper- ation green Module ready for operation Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 19: Display Element For Module Error

    The module has the LEDs Tx and Rx for displaying the data transfer (LEDs "Tx" and "Rx"). Descrip- Colour Status Signal tion - - - No data transfer green Send data - - - No data transfer green Receive data Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 20 EN 60068-2-30, EN 60068-2-78 In accordance with the standard Humidity 93 % r. h. at 40 °C Condensation during operation Not permitted EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61131-2 Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 21 Material Bottom Front Connection type D-Sub male connector Dimensions Height 128,9 mm Width 30,0 mm Depth 56,0 mm 81 g Weight Where standards are undated, the 2009-03 latest editions shall apply. Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...
  • Page 22 Labelling bracket, scope of supply: 5 pieces 312 966 PSSu A LA0 Labelling strips, laser printable, scope of supply: 1080 pieces 312 958 (10 x DIN A4 sheet, 108 on each) Operating Manual PSSu K S RS232 Modbus ASCII 1001689-EN-05...

This manual is also suitable for:

312 438Pssu k s rs232

Table of Contents