To connect a decentralised module (e.g. PDP67 F 8DI ION from Pilz), use a 5-pin unshiel-
ded cable with an A-coded M12 male connector (for connection to the decentralised mod-
ule) and an A-coded M12 female connector (for connection to the E-STOP device) (see
der reference [

Examples for connection to Pilz evaluation devices

Evaluation device
PNOZ s5
PNOZ m B0
PDP67 F 8DI ION
Operating Manual PIT es Set10u-5ns (AIDA) basic
1004863-EN-03
20]
"Connection cable for connection to decentralised modules").
Internal supply voltage
PNOZ s5
S11
S21
S12
S22
A2
PNOZ m B0
T0
M20
T1
M21
IM0
IM1
A2
PDP67 F 8DI ION
1
5
2
4
3
NOTICE
Check wiring
Particularly if you are using an open-ended cable, check the function of the
E-STOP pushbutton before commissioning the plant/machine by interrupt-
ing the GND connection of PIN 3. The evaluation device must then switch
off. When an evaluation device does not switch off, there is a wiring error.
External supply voltage (24 V)
PIT es Set10u-5ns
basic
(400 463)
1
5
2
4
3
PIT es Set10u-5ns
basic
(400 463)
PNOZ m B0
1
5
2
IM0
4
IM1
3
A2
PIT es Set10u-5ns
basic
(400 463)
1
5
2
4
3
Or-
L+
PIT es Set10u-5ns
basic
(400 463)
1
5
2
4
3
| 15