Supplementary Data; Permitted Operating Height; Order Reference; Product - Pilz PIT es Set10u-5ns (AIDA) basic Operating Manual

E-stop device
Hide thumbs Also See for PIT es Set10u-5ns (AIDA) basic:
Table of Contents

Advertisement

PIT es Set10u-5ns (AIDA) basic

Supplementary data

Permitted operating height

The values stated in the technical details apply to the use of the device in operating heights
up to max. 2000 m above sea level. When used in greater heights, constraints have to be
taken into account:
Permitted maximum operating height 5000 m
}
From an operating height of 2000 m the max. permitted ambient temperature is reduced
}
by 0.5 °C/100 m
Operating height
3000 m
4000 m
5000 m

Order reference

Product

Sets
Product type
Features
PIT es Set10u-5ns
Set consisting of E-STOP pushbutton active/inactive with flash func-
basic
tion, without logo and without E-STOP symbol, with contact block and
with LED safety printed circuit board in basic surface mount housing
with 5-pin M12 plug connection, 2 N/C (push-in technology connec-
tion)
PIT es Set10u-5ns
Set consisting of E-STOP pushbutton active/inactive with flash func-
AIDA basic
tion, without logo and without E-STOP symbol, with contact block and
with LED safety printed circuit board in basic surface mount housing
with 5-pin M12 plug connection - AIDA PIN assignment; 2 N/C (push-
in technology connection)
Emergency stop pushbutton
Product type
Features
PIT es10u
E-STOP pushbutton can be activated/deactivated without logo and
without E-STOP symbol
Operating Manual PIT es Set10u-5ns (AIDA) basic
1004863-EN-03
INFORMATION
A safety function's SIL/PL values are not identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.
Permitted ambient temperature
50 °C
45 °C
40 °C
Order no.
400 463
400 464
Order no.
400 540