DICKEY-john Radar Velocity Sensor

There are two possible locations for the DICKEY-
john Radar Velocity sensor. The sprayer is setup
with the radar sensor located in the right side pod
of the sprayer attachment.
radar sensor is physically protected.
If an erratic reading results during mature crop
spray applications or from other factors, the radar
sensor can be moved to the higher position in front
of the tank. The mounting bracket for the radar to
be mounted on the front of the tank, is above the
swing cylinder inside the right pod.
The calibration number that is programmed into
the MT-3405 rate controller is 1.60 (refer to the
MT-3405 Operator's Manual for instructions on
calibrating the controller). This calibration number
does not change with English or Metric units.
WARNING:
damage
from
emitted by the DICKEY-john Radar
sensor, do not look directly into
sensor face.
NOTE: The radar will not operate unless the
ignition key of the windrower is turned to the
"RUN" position.
OPERATION
In this location, the
To avoid possible eye
microwave
signals
Location of the DICKEY-john Radar
Radar can be mounted in front of the tank
for higher crop applications.
45
velocity sensor

Advertisement