Agitation

The MacDon Field Sprayer is supplied with two jet agitators installed in the front solution tank. The agitation
of your chemical mixture can be regulated by:
a. Changing the orifice in the agitator jet.
b. Using the agitation control valve C to throttle the bypass to obtain the desired maximum spray or
minimum spray pressure or tank agitation.
Orifice
1. The MacDon Field Sprayer is shipped from the
factory with the 3/16" orifice installed.
allows 12.8 USgpm (49.6 LPM) output per
agitator at 50 psi (345 kPa).
2. If the agitation control valve C is fully open, the
maximum pressure or agitation is obtained.
Minimum pressure is achieved by partially
opening or closing the agitation control valve C.
Changing the agitation orifice in the agitator jet will
change the pressure ranges obtainable with the
agitation control valve.