Setup functions
AC frequency **
AC waveform **
Half cycle AC
AC balance **
Negative ignition current *
Positive ignition current *
Positive ignition sequence time *
Ignition cycle total time */***
MIX TIG cycle time **
* Setting is always on ** Adjustable also by the Quick Setup *** Note panel software version
60
E1
50...250
Sqr
E2
Sin
5
E3
5...20
-25
-50...10
E4
100
100...500
E5
50
E6
30...150
10
E7
0...20
0.20
0.01...1,0
E8
0.6
0.1...1,0
E9
Factory setting 60 Hz
Adjustment range 50...250 Hz
Square wave
Sinus wave
Factory setting 5 A
Adjustment range 5...20 A
Factory setting -25 %
Adjustment range -50...10 %
Factory setting 100 %
Adjustment range 100...500 % (Limited by
the max. of the power source)
Factory setting 50 %
Adjustment range 30...150 % (Limited by the
max. of the power source)
Factory setting 10 = 0,01 s
Adjustment range 0...20 = 0,0...0,02 s
Setting 0,20 s.
Adjustment range 0,01...1,0 s.
Factory setting
Adjustment range 0,1...1,0 s.