Technical data

Mains Voltage
Mains cable
Fuse
Rated power
Minimum Current
Open circuit Voltage
Power Factor at nominal values
Efficiency at nominal values
Open circuit power
Electrode sizes to be welded
Size ( l x w x h )
Weight
Maximum power can be achieved with 20 kVA generator for the power source.
The device may be repaired only by a person legally authorized
perform electric work!
Measured values may differ by the type and model of multimeter used.
3 ~ 230 V - 10% ... 460 V +10%, 50/60 Hz
H07RN-F 4G2.5, length 5 m
20/ 16A delayed fuse
40%
TIG
300A
MMA
250A
TIG 3A ( AC 5A ) / MMA 10A
58 V
0,95
80-84 % (250A / 30V)
77-81 % (300A / 22V)
TIG < 13W
MMA 190W
1,5 - 5,0 mm
500 x 180 x 390 mm
25 kg
100%
TIG
190A
MMA
190A
2

Advertisement