8
Adjustable Range Reflective Photoelectric Sensor
PRECAUTIONS FOR PROPER USE
Wiring
• Check all wiring before applying power since incorrect
wiring may damage the internal circuit. Also, carefully
tighten the terminal screws so that the wires of adjacent
terminals do not touch.
• The mounting hole for the terminal cover fixing screws
inclines 70 degrees to the terminal cover, as shown in the
figure below.
To avoid damaging this product or screw, take care when
tightening or loosening a screw.
• To maintain water-resistance, the cable should have
an outer diameter between ø9 to ø11 mm
ø0.433 in
with a smooth covering material that allows the
attached conduit connector to be securely tightened; the
tightening torque of the screw should be of 1.5 to 2.0 N·m.
• If an external surge voltage exceeding 4 kV is impressed
(DC-voltage type: 1 kV), the internal circuit will be
damaged, and a surge suppressing element should be
used.
• Prepare the cable end as shown below.
Conduit connector construction and cabling
Conduit connector
Gland packing (Note)
Note: When assembling the conduit connector, pay attention to the direction
of the gland packing.
Furthermore, in order to maintain water-resistance, fit the gland
packing such that the seating surface of the gland packing contacts
the packing holder part of the terminal cover evenly.
• The size of conduit is M20 × 1.5 mm
• If pressure terminals are to be used, affix the connected
pressure terminals to a terminal (M3.5 screw).
Dimensions of the suitable crimp terminals
Round type
ø 3.6
22
0.866
ø 0.142
or less
or more
10
0.394
or less
7.5
0.295
or less
17
0.669
or less
(After crimping)
Note: Use crimp terminals with insulating sleeves.
Recommended crimp terminal: Nominal size 1.25 × 3.5
• The tightening torque for the terminal screws should be
0.3 to 0.5 N·m.
EQ-500
Screw for terminal cover fixing
Screwdriver
ø0.354 to
37 mm
1.457 in
Power supply
Output
25 mm
Gland
0.984 in
0.787
in.
(Unit: mm in)
Y-shaped type
22
0.866
3.6
0.142
or less
or more
10
0.394
or less
7.5
0.295
7
0.276
or less
or less
17
0.669
or less
(After crimping)
0.049 ×
SERIES

Part description

Stability indicator (Green)
Distance adjuster (2-turn)
Adjuster indicator
Operation indicator (Orange)
Notes: 1) The operation mode switch of the DC-voltage type is the DIP switch.
Refer to "DC-voltage type" of
2) Incorporated on EQ-5□T only.
Operation mode switch
Multi-voltage type (L-ON/D-ON mode only)
Operation mode switch
Note: Turn the operation mode switch gradually and lightly with the attached
screwdriver. Turning with excessive strength will cause damage to the
adjuster.
DC-voltage type
L-ON/D-ON mode
BGS/FGS mode
Timer mode
Not used
BGS/FGS function (DC-voltage type only)
• DC-voltage type sensor incorporates BGS/FGS function.
Select either the BGS or FGS function depending on the
positions of the background and sensing object.
• BGS/FGS function is set with the operation mode switch.
• FGS function is used when the sensing object contacts
the background (conveyor, etc).
• Depends on a selection of either BGS or FGS function,
the output operation changes as follows.
Non-detectable area
L-ON
7
0.276
BGS
or less
D-ON
L-ON
FGS
D-ON
0.138.
OFF-delay timer adjuster (Note 2)
ON-delay timer adjuster (Note 2)
Operation mode switch (Note 1)
"Operation mode switch"
Description
Detection-ON mode is obtained when the switch
is turned fully clockwise (L side).
Detection-OFF mode is obtained when the switch
is turned fully counterclockwise (D side).
L
D
BGS
FGS
OFF
Timer ON
N.C.
N.C.
Detectable range
Setting distance
for details.
ON
OFF
ON
OFF
ON
OFF
ON
OFF

Hide quick links:

Advertisement

Table of Contents
loading