Power

The power status menu is entered from the STATUS menu by pressing SELECT. Press SELECT to see the voltage of the
power module. Press NEXT to display the estimated remaining life of the power module.
Note
The remaining life value of the power module is an estimate. The life span of the power module is affected by many operating
conditions, including: Power module type. The update or burst rate of the 4320 wireless position monitor. The number of devices
operating through this device to the gateway and their update or burst rates. Network changes causing more or less traffic
through the device; for example, a failure in another wireless device in the mesh network, resulting in re‐routing, forcing more
traffic through the device. Temperature extremes (both high and low) will also affect the life span of the power module.
From the power module life display, press NEXT to go back to the Power menu. Press NEXT to enter the Network
menu.

Network

Access the Network screen by pressing the right button (STATUS), the left button (SELECT), and then the right button
(NEXT) again.
Press SELECT to display the NETWORK ID configured in the device. Press NEXT to show the current network
operational state:
SEARCHING—the device is waiting to detect the presence of a wireless network with the same Network ID and join
key.
NEGOTIATING—the presence of a wireless network with the same network parameters has been detected and the
device is attempting to join the network.
CONNECTED—the device has detected the presence of a wireless network with the same network parameters and
has successfully joined the network.
OPERATIONAL—the device is operating within a wireless network.
DISCONNECTED—the device has become disconnected from the wireless network.
IDLE—the device has been instructed by a HART command not to attempt to participate in a wireless network.
Press NEXT to return to the Network menu.
Press the NEXT in the Network menu to see the TAG of the device. Press NEXT to view the Set Point for devices with the
on/off control option. Press the right button to view the current position of the valve or monitored equipment.
The top reading indicates % of SPAN, the state of the valve (OPEN, PARTIALLY OPEN, or CLOSED) is on the bottom line.
Press the right button to return to the STATUS menu.
Press NEXT while in the STATUS menu to access the CALIBRATE menu.
4320 Position Monitor