VAT 642 GP Series Installation, Operating, & Maintenance Instructions page 71

Table of Contents

Advertisement

Series 642
Command
®
(DeviceNet
term
if deviant)
SENSOR MODE
SENSOR RATIO
ZERO CONTROL
ZERO
Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values
are indicated by the letter 'h' (e.g. 31h)
605593EC
INSTALLATION
Service Code
Class ID
Set
16
49
Get
14
49
X:
0
no sensor
1
1 sensor operation (sensor 1 input)
2
2 sensor operation with automatic changeover
(low range = sensor 2 input, high range = sensor 1 input)
3
1 sensor operation (sensor 2 input)
4
2 sensor operation with automatic changeover
(low range = sensor 1 input, high range = sensor 2 input)
This command controls / returns the sensor mode for pressure control.
Sensor modes 2, 3 and 4 are possible with 2 sensor hardware [642 . . - . . . Q - .
. . . ] only.
For applications where the high range sensor is used for for monitoring purpose
only, select sensor operation modes 1 or 3 for pressure control with low range
sensor and read high range sensor from SENSOR 1 READING resp. SENSOR
2 READING.
Set
16
49
Get
14
49
X:
sensor ratio according to selected DATA TYPE, range is 100 ... 10'000
This command defines the sensor ratio for 2 sensor operation.
Sensor ratio = high range sensor full scale / low range sensor full scale * 100.
Set
16
49
Get
14
49
X:
0
Disable
1
Enable
This command enables resp. disables the ZERO command. In case it is disabled ZERO
does not work.
75
49
This command initiates ZERO.
Refer to «ZERO (setup step 4)» for correct zero procedure.
Edition 2017-11-24
Instance ID
Attribute ID
1
101
1
101
1
103
1
103
1
102
1
102
1
-
Service
Service
data length
data field
(number of bytes)
1
X
1
2 or 4
X
2 or 4
1
X
1
2 or 4
0
71/113