4.6.8.1
Pressure controller
Configuration of three possible pressure controller.
('Control View' or 'Control Performance Analyzer')
4.
Open CV or CPA
5.
Go to «Tools» > «Terminal» and send setup command s:02 according to
application needs. (possibility of adjustment see below)
s:02Z00a
Set
configure pressure controller a
i:02Z00
Get
get the actual pressure controller a
This command selects pressure controller.
a
Pressure controller
0 = Adaptive downstream
1 = Fixed 1
2 = Fixed 2
3 = Soft pump
For easy setup (Local operation) of 'Pressure controller' and 'Pressure control parameter' please
use the VAT "Control Performance Analyzer" CPA 3.0.
There is a free download on the VAT home page, refer to: http://www.vatvalve.com/customer-
service/informations-and-downloads/control-performance-analyzer
4.6.8.2
With CPA 3.0 direct setup (standard)
Open the CPA. In menu 'Pressure Control' / 'Setup', select the 'Pressure controller' and do the setup for
pressure control algorithm (parameter).
40/113
Local operation:
Command
(within 10ms after reception of
Describtion
s:02
i:02Z00a
Edition 2017-11-24
INSTALLATION
Acknowledgement
command)
Series 642
Remote operation:
It's not possible to do
'Pressure controller configuration'
via remote operation.
605593EC