VAT 642 GP Series Installation, Operating, & Maintenance Instructions page 70

Table of Contents

Advertisement

Command
®
(DeviceNet
term
if deviant)
CHANGE OF STATE /
CYCLING INPUT
ACCESS MODE
POWER UP
CONFIGURATION
POWER FAIL
CONFIGURATION
Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values
are indicated by the letter 'h' (e.g. 31h)
70/113
INSTALLATION
Service Code
Class ID
Set
16
5
Get
14
5
X:
input assembly object number (3, 4, 5, 13, 14, 100, 101)
This command configures resp. reads the input assembly for change of state / cycling.
Set
16
100
Get
14
100
X:
0
Local (operation via service port)
1
Remote (operation via DeviceNet
2
Locked (in remote mode)
This command controls / returns the access mode of the valve.
Set
16
100
Get
14
100
X:
0
closed
1
open
This command controls / returns the valve position after power up.
Set
16
100
Get
14
100
X:
0
closed
1
open
This command controls / returns the target valve position in case of a power failure.
Only for versions that have Power Fail Option equipped [642 . . - . . C . - . . . . or
642 . . - . . H . - . . . . or 642 . . - . . U . - . . . . or 642 . . - . . W . - . . . .].
Edition 2017-11-24
Instance ID
Attribute ID
4
101
4
101
1
107
1
107
®
)
1
112
1
112
1
113
1
113
Series 642
Service
Service
data length
data field
(number of bytes)
1
X
1
1
X
1
1
X
1
1
X
1
605593EC

Advertisement

Table of Contents
loading

Table of Contents