GRAUPNER MC-20 HoTT Programming Manual page 245

Table of Contents

Advertisement

Channel sequencer
10
11
12
0
STEP
TIME
Use one of the
selection keys of the right touch
pad, as necessary, to shift the marker frame to the
right from the column "TIME" to the value fi eld above
the column labeled "POS" then, after a tap on the
center
SET
key of the right touch pad, alter this value
within a range of ±100 % until the servo is in the
desired initial position. For example:
Channell sequencer
10
11
12
0
STEP
TIME
Repeat this procedure as necessary for the other two
servos.
With a simultaneous tap on the
keys of the right touch pad (CLEAR), the given
position value will be reset back to"0 %".
Step 1: fi rst event
Now that initial positions have been established, the
fi rst step can be set. This is a matter of defi ning what
is to be done, or not done, fi rst, following a certain
span of time.
Do this by fi rst using the
selection keys of the left
touch pad to select one of the servos. Now tap the
key of the left touch pad. The step number, which
was previously indicated by a "0" is now replaced
by a "1" and the value "0.0s" will appear in the fi eld
above "TIME".
10
11
0%
–––
12
POS
1
STEP
Use the selection keys of the right touch pad as
necessary to shift the marker frame to the "TIME"
column.
Now briefl y tap on the center
touch pad to set the activation time into the value
fi eld for the "TIME" column, e.g. 1.5 s. The current
position in time is represented in the graphic by the
dotted vertical line. It will move to the right according
to the time setting and, at the same time, the course
of servo positions will be presented as dotted lines
between time-point "0" and time-point "1".
+90%
–––
POS
10
11
or
selection
12
1
STEP
Now set the desired servo positions for the end of the
fi rst time span (with the same procedure as already
described for "Step 0") or leave one or more of these
servos in the same position they were in for the
previous step.
A simultaneous tap on the
touch pad (CLEAR) will reset the inverse video value
displayed if the TIME fi eld back to "blank" and erase
the current sequence, in this example only Step "1".
Channel sequencer
0.0s
+90%
–––
TIME
POS
SET
key of the right
Channel sequencer
1.5s
+90%
–––
TIME
POS
or
keys of the right
Channel sequencer
10
11
12
0
0.0s
STEP
TIME
Step 2 ...
Repeat the previously described procedure for
every other step to be defi ned until the servos have
reached their terminal positions.
Switch assignment
In conclusion, assign the sequence of events created
to a switch (as described on page 56 in the section
"Assigning transmitter controls, switches and control
switches") with which the servos can be switched
between their initial and terminal positions.
Channel sequencer
10
11
12
8
0.0s
STEP
TIME
As soon as this switch is closed, the servos'
sequence of movements can be followed in the
graphic. The servo curves will be shown in inverse
video according to the preset time windows. All
movements will sequence in reverse when the switch
is opened again.
Important notices:
The sequence shown is only for demonstration
purposes and is not at all representative of a real
sequence of servo movements.
Detail program description - Channel sequencer
+90%
–––
POS
0%
2
POS
245

Advertisement

Table of Contents
loading

This manual is also suitable for:

32032

Table of Contents