GRAUPNER MC-20 HoTT Programming Manual page 236

Table of Contents

Advertisement

for either "SERVO" or "SENSOR".
This switchover is accomplished by moving the
with the selection key of the left or right touch pad
until the " " symbol is at the left margin of the bottom
line then tapping on the center
SET
touch pad.
TELEMETRY
RX CURVE
CURVE1 CH
:
02
TELEMETRI RCV
TYPE :
SETTING & DATAVIEW
CURVE2 CH
:
03
TYPE :
SENSOR SELECT
CURVE3 CH
:
04
RF STATUS VIEW
TYPE :
5CH
FUNCTION:SERVO
VOICE TRIGGER
Now use one of the
selection keys on the right
touch pad to select the alternative setting "SENSOR".
TELEMETRY
RX CURVE
CURVE1 CH
:
02
TELEMETRI RCV
TYPE :
SETTING & DATAVIEW
CURVE2 CH
:
03
TYPE :
SENSOR SELECT
CURVE3 CH
:
04
RF STATUS VIEW
TYPE :
5CH
FUNCTION:SENSOR
VOICE TRIGGER
Another tap on the center
SET
key of the right touch
pad will close the selection and, with appropriate
repetitive taps on the center
ESC
key of the left touch
pad, a return to the transmitter's basic display is
accomplished.
236 Detail program description - Telemetry
RX SERVO TEST
TELEMETRY
TELEMETRI RCV
key of the right
SETTING & DATAVIEW
SENSOR SELECT
RF STATUS VIEW
VOICE TRIGGER
BIND. 1
A
Value
A
B
ALL-MAX
ALL-MIN
BIND. 1
A
TEST
A
ALARM
B
VOLT
ALARM
TEMP+
ALARM
TEMP–
CH
OUTPUT
TYPE
RX SERVO TEST
ALL–MAX
: 2000 sec
BIND. 1
ALL–MIN
: 1000 sec
TEST
: STOP
ALARM VOLT : 3.8V
ALARM TEMP+: 70°C
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
Explanation
Possible
settings
Servo travel on the
1500 ... 2000 μs
"+" side for all servo
outputs for the
servo test
Servo travel on the
1500 ... 1000 μs
"-" side for all servo
outputs for the
servo test
Test procedure
START / STOP
Alarm threshold
3.0 ... 6.0 V
of the receiver
factory setting:
undervoltage
3.8 V
warning
Alarm threshold for
50 ... 80 °C
excessively high
Factory setting:
temperature of the
70 °C
receiver
Alarm threshold
-20 ... +10 °C
for excessively low
Factory setting:
temperature of the
-10 °C
receiver
Channel sequence
ONCE, SAME,
SUMI, SUMO
ALL-MAX (servo travel on the "+" side)
In this line you set the maximum servo travel on the
plus side of the control travel for the servo test.
2000 μs corresponds to the full throw; 1500 μs
corresponds to the neutral position.
Make sure that the servos do not overrun
mechanically during the test routine.
ALL-MIN (servo travel on the "-" side)
You adjust the maximum servo travel on the minus
side of the control path for the servo test in this line.
1000 μs corresponds to the full throw; 1500 μs
corresponds to the neutral position.
TEST
You start and stop the servo test integrated in the
receivers in this line.
A brief tap on the center
SET
key of the right touch
pad will open the entry fi eld:
TELEMETRY
RX SERVO TEST
TELEMETRI RCV
ALL–MAX
: 2000 sec
ALL–MIN
: 1000 sec
SETTING & DATAVIEW
TEST
:
STOP
ALARM VOLT : 3.8V
SENSOR SELECT
ALARM TEMP+: 70°C
RF STATUS VIEW
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
VOICE TRIGGER
Now, with one of the selection keys of the right touch
pad, select START:
TELEMETRY
RX SERVO TEST
ALL–MAX
: 2000 sec
TELEMETRI RCV
ALL–MIN
: 1000 sec
SETTING & DATAVIEW
TEST
:
START
ALARM VOLT : 3.8V
SENSOR SELECT
ALARM TEMP+: 70°C
RF STATUS VIEW
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
VOICE TRIGGER
A brief tap on the center
SET
key of the right touch
pad will now start the test run. The input fi eld is
BIND. 1
BIND. 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

32032

Table of Contents