Speed Alarm - Suzuki SMD16 Operator's Manual

Multi-function display
Hide thumbs Also See for SMD16:
Table of Contents

Advertisement

[Over] or [Under]
The [Over] or [Under] alarm sounds when the temperature is over or under the set
value, respectively.
1) Tap [Temperature Alarm Value] to display the software keyboard.
2) Set the value, then tap []. Go to step 3.
[Within] or [Out of]
The [Within] or [Out of] alarm sounds when the temperature is within or out of the
temperature range set, respectively.
1) Tap [Temp. Alarm Range Min Value] to display the software keyboard.
2) Set the minimum value, then tap [].
3) Tap [Temp. Alarm Range Max Value] to display the software keyboard.
4) Set the minimum value, then tap []. Go to step 3.
[Shear]
The shear alarm sounds when the temperature exceeds the alarm setting for one
minute.
1) Tap [Temp. Shear Alarm Value] to display the software keyboard.
2) Set the value, then tap []. Go to step 3.
3. Tap the close button to finish.
3.10.4

Speed alarm

The speed alarm tells you when the speed of your ship is over or under the limit set.
Set the value at [Speed Alarm Value].
1. Tap [Speed Alarm] on the [Alarm] menu.
2. Tap [Over] or [Under].
3. Tap [Speed Alarm Value] to display the software keyboard.
4. Set the value for [Over] or [Under] then tap [].
5. Tap the close button to finish.
3. PLOTTER
3-15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smd12

Table of Contents