13.4

Proximity AIS Target Alarm

The proximity AIS target alarm alerts you when an AIS target is within the distance you
specify, and is applicable to both displayed and not displayed targets. When an AIS
target is within the distance set, the alarm indication "Proximity AIS Alarm" flashes in
the status bar and the audio alarm sounds. (See paragraph 3.10.8).
1. Open the home screen, then tap [Settings] - [Targets].
2. Turn on [Proximity AIS Target Alarm].
3. Tap [Proximity AIS Target Alarm Value] to open the software keyboard.
4. Set the alarm value, then tap [].
5. Tap the close button to finish.
13.5

How to Ignore Slow Moving AIS Targets

The proximity AIS target alarm may often sound in areas of heavy vessel traffic. You
can prevent frequent release of the alarm against slow, non-threatening targets by
specifying the maximum target speed that triggers the alarm. Any target whose speed
is lower than set here does not trigger the alarm.
1. Open the home screen, then tap [Settings] - [Targets].
2. Tap [Ignore Alarms for AIS Slower than...] to open the software keyboard.
3. Set a speed, then tap []. The setting range is 0.0 - 9.9 (knots).
4. Tap the close button to finish.