FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must
be lighted by hand. When lighting the
pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the floor because some
gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do
WARNING: You must oper-
ate this heater with the screen
in place. Make sure screen is
installed before running heater.
NOTICE: During initial operation of
new heater, burning logs will give
off a paper-burning smell. Orange
flame will also be present. Open
damper or window to vent smell.
This will only last a few hours.
1. STOP! Read the safety information above.
2. Open screen.
3. Make sure equipment shutoff valve is fully
open.
4. Turn control knob clockwise
OFF position (see Figure 21).
5. Wait five (5) minutes to clear out any gas.
Then smell for gas around heater and
near the floor. If you smell gas, STOP!
Follow "B" in the safety information above.
If you do not smell gas, go to the next step.
200348-01C

OPERATION

LIGHTING INSTRUCTIONS
to the
www.usaprocom.com
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don't try to repair it, call a
qualified service technician. Force or
attempted repair may result in a fire or
explosion.
D. Do not use this appliance if any part
has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part of
the control system and any gas control
which has been under water.
6. Turn control knob counterclockwise
to the PILOT position. Press in control
knob for five (5) seconds.
Note: The first time that the heater is
operated after connecting the gas supply,
the control knob should be pressed for
about thirty (30) seconds. This will allow
air to bleed from the gas system. If pilot
does not stay lit, refer to Troubleshooting,
pages 24 though 27. Also contact a quali-
fied service technician or gas supplier for
repairs. Until repairs are made, light pilot
with match.
• If control knob does not pop up when
released, contact a qualified service
technician or gas supplier for repairs.
ON/OFF
Ignitor
Switch
Figure 21 - Heater Control Locations
Control Knob
19