OPERATION

FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
personal injury, or loss of life.
NOTICE: During initial operation of new heater, burning logs will give off a paper burning smell. Orange flame will also be
present. Open a window to vent smell. This will last only a few hours.
CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.
A. This appliance has a pilot which must be lit by the electronic ignitor. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push control. Never use tools. If the appliance does not operate, don't try to repair it. Call a qualified
service technician or gas supplier. Forced or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any gas control, which has been under water.
Note: Please wait one minute after shutting off fireplace to allow the control valve to reset before starting again.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information on page 3.
2. Unscrew ignitor cap and install a AAA type battery with its anode ("+") pointing out. Replace cap
3. Make sure equipment shutoff valve is fully open.
4. Warning: You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is installed before
running fireplace.
5. Turn control knob clockwise to the OFF position, see Figure 14.
6. Wait five (5) minutes to clear out any gas. Then smell for gas around heater and near floor. If you smell gas, STOP! Follow
"B" in the safety information on Warnings plate. If you don't smell gas, go to the next step.
7. Turn control knob counterclockwise to the PILOT position. Keep control knob pressed in for five (5) seconds. Note: You may
be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for
30 seconds. This will allow air to bleed from the gas system. If control knob does not pop up when released, contact a
qualified service person or gas supplier for repairs.
8. With control knob pressed in, push and hold ignitor button. This will light pilot. The pilot is attached to the rear of the front
burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service
person or gas supplier for repairs. Until repairs are made, light pilot with match.
9. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
Note: If pilot goes out, repeat steps 3 through 8. This heater has a safety interlock system. Wait one (1) minute before
lighting pilot again.
10. Warning: Make sure while the input gas type is NG, pilot burner NG ignites; while the input type is LP, pilot burner LP ignites.
Note: If you find anything abnormal in this step, repeat steps 2 through 8.
11. Turn control knob counterclockwise to the desired heating level. The main burner should light. Set control knob to any heat
level between HI and LO (5 –1).