Vent-free gas system
Table of Contents

Advertisement

WARNING: Failure to posi-
tion the parts in accordance
with these diagrams or failure
to use only parts specifically
approved with this heater may
result in property damage or
personal injury.
CAUTION: After installation
and periodically thereafter,
check to ensure that no yellow
flame comes in contact with any
log. With the heater set to High,
check to see if yellow flames
contact any log. If so, reposi-
tion logs according to the log
installation instructions in this
manual. Yellow flames contact-
ing logs will create soot.
It is very important to install the
logs exactly as instructed. Do
not modify logs. Use only logs
supplied with heater. Each log
is marked with a number. This
number will help you to identify
the logs when installing. After
installing logs, add decorative
cinders around the grate base,
do not place any decorative
cinders on logs or burner.
1. Install pins on log #1 into the two slots
in the bracket attached to rear wall (see
Figure 16).
2. Install pins on log #2 into the two slots in
left side of the middle bracket (see Figure
16 and Figure 17).
3. Install pins on log #3 into the two slots
in right side of the middle bracket (see
Figure 16 and Figure 17).
200348-01C
INSTALLATION
INSTALLING LOGS
Slots for Log #2
Slots for Log #4
Figure 17 - Installing Logs #2 and #3
www.usaprocom.com
Slots in Rear Plate
Log #1
Slots for Log #3
Figure 16 - Installing Log #1
Log #2
Log #3