Fault Messages In The Log Book - ProMinent Sigma2 S2Cb Operating Instructions Manual

Diaphragm motor-driven metering pump
Table of Contents

Advertisement

Troubleshooting
No.
Description
3
The number of defective strokes permitted has been exceeded
4
The diaphragm rupture sensor reports a diaphragm rupture
5
The stroke length has been modified beyond the tolerance limit with the pump locked
6
Overload warning
7
Temperature warning
8
An HMI is connected to a CANopen pump - bus operation and HMI are not permitted simultane‐
ously
14.5.2

Fault messages in the log book

Message no.
Description
33
The float switch input reports no feed chemical
34
In
memory is switched on. (Memory counter ≥ 100 000)
35
The analogue current is ≤ 3.8 mA when current monitoring is switched on. (Monitoring is always
switched on in Standard operating mode 4..20 mA).
36
The analogue current is > 23 mA when current monitoring is switched on. (Monitoring is always
switched on in Standard operating mode 4..20 mA).
37
The number of defective strokes permitted has been exceeded
38
The diaphragm rupture sensor reports a diaphragm rupture
39
The stroke length has been modified beyond the tolerance limit with the pump locked
40
Different version statuses of the CTRL, PFC and FC communication software
41
The HMI version is not compatible
42
System, EEPROM error
43
Communication between the pump and operating unit is not working although an operating unit
has been configured
44
Missing ongoing connection to the optional module
(Bus fail e.g. PROFIBUS or CANopen not active)
45
The optional module is missing or no communication is established with the optional module
46
One of the signals needed from the frequency converter (FC) is missing or no communication is
established between the FC and CTRL
46
One of the signals needed from the power unit (PFC) is missing or no communication is estab‐
lished between the PFC and CTRL
47
Over-temperature error
48
Shut-down in the event of overpressure
49
Error in the power end
50
Missing or defective position sensor
51
Mains voltage missing and/or over-/undervoltage
52
Fan error
53
Error in the intermediate circuit voltage
54
The 5 V at the DFM input has short circuited
55
An optional module was inserted into the pump, which cannot be used.
56
Subscriber software is incompatible with the other subscribers
82
'Batch' or 'Contact' operating mode, a memory overload has been reached when the