Namur sensor (Specified for EX zones)
16.9

Relay

16.10 Gear oil

16.11 Sound pressure level

Sound pressure level
For safety reasons we recommend connecting to a
protective low voltage, e.g. in accordance with EN
60335-1 (SELV ).
The cable can be poled as required.
5–25 V DC, in accordance with Namur or DIN 19234, potential-free
design.
Data
Rated voltage *
Power consumption - active surface
uncovered
Power consumption - active surface cov‐
ered
Rated switching distance
* Ri ~ 1 kΩ
Cable colour
Polarity
blue
-
brown
+
The technical data for the relay are contained in the
chapter "Installation, electrical".
Manufac‐
Name
Viscosity
turer
class
(ISO
3442)
Mobil
Mobil
VG 460
Gear 634
*
* or comparative gear oil
Sound pressure level LpA < 70 dB according to EN ISO 20361
at maximum stroke length, maximum stroke rate, maximum back pressure
(water)
Technical data
Value Unit
8 VDC
> 3 mA
< 1 mA
1.5 mm
Order No.
Quantity
1004542
1.0 l
Quantity,
required
0.5 l