35.3 Erase Running-Configuration

Follow the steps below to clear current configuration on the Switch. Note that this will NOT reset the
Switch back to its factory defaults. If you want to change the Switch to its factory default mode, click
the Factory Default button in Reboot System.
In the Maintenance screen, click the Click Here button next to Erase Running-Configuration to clear all
1
Switch configuration information you configured you configured on the Switch.
Click OK to remove the running configuration on the Switch.
2
Figure 202 Erase Running-Configuration: Confirmation
In the web configurator, click the Save button in the top of the screen to make the changes take effect.
3
If you want to access the Switch web configurator again, you may need to change the IP address of
your computer to be in the same subnet as that of the default Switch IP address (192.168.1.1 or DHCP-
assigned IP).

35.4 Save Configuration

Click Config 1 to save the current configuration settings permanently to configuration one on the
Switch.
Click Config 2 to save the current configuration settings permanently to configuration two on the Switch.
Click Custom Default to save the current configuration settings permanently to a custom default file on
the Switch. If configuration changes cause the Switch to behave abnormally, click Custom Default (next
to Reboot System) to have the Switch automatically reboot and restore the saved Custom Default
configuration file.
Alternatively, click Save on the top right-hand corner in any screen to save the configuration changes
to the current configuration.
Note: Clicking the Apply or Add button does NOT save the changes permanently. All
unsaved changes are erased after you reboot the Switch.