To simplify the replacement of the HRA, you need to remove some library panels to allow
access to key areas inside the libraries.
Move the Library System
There must be at least 3.5 feet (1.1m) of clear space beside the library to allow enough room
to remove the HRA from the connected NEO 8000 libraries. If there is not enough room, it is
necessary for you to move the library system.
Refer to
Appendix A, "Moving the Libraries,"
libraries.
Power Down the Libraries
WARNING: Working with a powered NEO 8000 library may cause physical harm and
severe damage to unit's circuitry. Always power down a library before removing any
panels.
1. Power down both units at the front panel.
2. Set each of the library circuit breakers to the OFF ("O") position.
3. Remove and retain the power cords.
Remove the Side Panels
Remove the outside side panels from both libraries.
1. At the Master unit, remove the screws that secure the left panel and carefully
remove the panel.
2. At the Slave unit, remove the screws that secure the right panel and carefully
remove the panel (see
Part Number 104372-102 08/2005
Chapter 2: Prepare the Libraries
Slave
Master
Figure 2-1: Clearance Needed for HRA Removal
Figure
2-2).
3.5 feet
for information about moving and leveling the
2–1