5. Using a wrench, turn each leveler 3-4 turns counterclockwise to raise it off the floor.
6. Using at least 2 people, roll the library system to an open location.
Continue with the standard removal and replacement of the HRA.

Move the Library System Back in Place

Once the new HRA is in place, you can move the library system back to its original position.
1. Using at least 2 people, roll the library system back in place aligning the levelers with
the appropriate reference marks on the floor.
2. Using a wrench, turn each leveler 3-4 turns clockwise until it makes firm contact with
the floor and lines up with the reference marks.
3. Place a 6" to 10" (15–25cm) level, front to rear, on the middle-right drawer slide
housing on the Slave unit (see
4. Note the position of the bubble. If necessary, raise all four of the front feet or all four of
the rear feet the same amount to achieve a level front-to-rear reading.
5. Place a 36" (90cm) level across one of the mounting brackets.
NOTE: The access plates must be removed to allow viewing of the level.
6. Note the position of the bubble. Using a wrench, raise both of the left feet or both of the
right feet the same amount to achieve a level side-to-side reading.
7. Once the unit is level side-to-side, use a wrench to snug down the center four levelers.
8. Recheck the level from front-to-rear and from side-to-side. Adjust as needed to level
the library.
A–2
Figure

Figure A-2: Placement of Small Level on Slide Housing

A-2).