reset to defaults.
If we update both BIOS and ME images, in order to make ME firmware take effect, it is
suggested to start the server after AC power off.
Step 1
Login Management Web GUI, enter "Administrator -> BIOS Firmware Update", as shown
below. Select BIOS+ME or BIOS only, BIOS+ME by default. If you want to preserve BIOS
setup options, users need select "BIOS Setup Options". PHY MAC is selected to be preserved
by default. Click "Enter Firmware Update Mode" button to enter update mode.
Step 2
Select image file, and click Upload button to upload file. ME will enter recovery mode, and
then BMC will verify the image. Verify:
Size should be 32M.
Verify image integrity, it will make sure this is BIOS image.
If the verification fails, BMC will stop flash and change ME to normal mode.
If the verification succeeds, click "Proceed to Update" button to start update. Wait for about
3 mins, then the flash is complete, and ME will enter the normal mode.
166
Figure 9-56 BIOS Update Step 1
Figure 9-57 BIOS Update Step 2