Event Alerting - Inspur NF5280M5 User Manual

Table of Contents

Advertisement

9.9.4 System Serial Log
Refer to section "Serial over LAN (SOL) and System Serial Log Recording".

9.10 Event Alerting

BMC supports SNMP Trap and SMTP email alerts.
9.10.1 SNMP Trap Alert
BMC supports SNMP Trap. Users open trap receiver and set trap destination IP in BMC Web
GUI. When BMC detects event, BMC will send event to the trap receiver.
BMC supports SNMP v1, v2, v3 traps. Default Trap v1.
A Modular Information Block (MIB) file associated with the traps should be provided with
the BMC firmware to help SNMP Trap receiver to translate the trap.
SNMP default port number is 162, users can set port in Chapter "Service".
Only IPMI sensor based log supports SNMP Traps.
Step 1
Set SNMP Trap protocol, including Trap version, event severity filtering, and community
.etc. As bellow:
Step 2
Set event filter, users can select sensor type or sensor name.
Figure 9-29 Alert Settings