9.21.4 Power Limit
BMC provides power cap function, power cap function sets the power limit for the system,
and when the system power exceeds this upper limit, Intel ME will slow down the CPU to
reduce power consumption. Power cap will affect the server performance, professional
maintenance personnel will operate when needed.
Go to page "Power and Fan->Power Consumption" to check and configure.
9.21.5 Power Consumption Statistics and History Record
BMC provides curve-based inlet temperature and power monitoring statistics.
Administrators can gain insight into the actual use of electricity and cooling resources
through energy monitoring devices. Users can optimize the server's energy savings based on
historical data.
Go to page "Power Management-> Power statistics", and this page displays the system
current power, CPU total power, total memory power and a specific period of peak power,
average power, the cumulative power consumption.