Scr System Tampering Driver Warning And Inducement - PREVOST X3-45 COACH 2018 Operator's Manual

Table of Contents

Advertisement

5-10
Other Features

SCR SYSTEM TAMPERING DRIVER WARNING AND INDUCEMENT

Conditions / Triggers
1 Normal
No diagnostic troubleshooting code active
2 SCR
system
tampering
troubleshooting code confirmed
3 Reached one (1) hour of operation with active
SCR
system
tampering
troubleshooting code confirmed
4 Reached four (4) hours of operation with active
SCR
system
tampering
troubleshooting code confirmed
5 Diesel fuel refueling done with a fuel level sensor
increase of 15% or more
Amber Warning Light, Did Message And Audible
None
SCR SYSTEM FAULT 
diagnostic
SERVICE SYSTEM AT NEXT STOP 
solid 
SCR SYSTEM FAULT 
diagnostic
ENGINE IN DERATE 
solid
5 MPH  (8KM/H) LIMIT IN < XXX MINS 
SCR SYSTEM FAULT 
diagnostic
REPAIR NEEDED 
solid
5 MPH (8KM/H) LIMIT NEXT 20MIN 
VEHICLE STOP 
SCR SYSTEM FAULT 
VEHICLE SPEED LIMITED TO 5 MPH (8 
solid
KM/H) 
beeps
PA1627 X3-45 Operator's Manual
Warning
3 cycles of 2 beeps
3 cycles of 2 beeps
3 cycles of 2 beeps
continuous cycle of 2
Inducement
None
Warning message
Engine
torque
reduction of 25%
Engine
torque
reduction of 40%
Vehicle road speed
limited (RSL) to 5 mph
(8 km/h)