Aftertreatment

This menu permits to the driver to initiate a stationary regeneration, to check the status of the
aftertreatment system and to interrupt regeneration.
1.
Request Parked REGEN
Use this function to initiate a stationary (parked) regeneration.
2.
ATS Status
The Aftertreatment status sub-menus provide information about the
conditions required for performing regeneration. The status can be OK
(regeneration allowed), CHECK (regeneration not allowed) or N/A (not
applicable). When ATS Status is selected, the following sub-menus are
available.
Soot Level Gauge
From the ATS Status sub-menu, you can view the soot level for the
Aftertreatment system. When the soot level is high, regeneration is
necessary. L1, L2, L3 and L4 under the scale correspond to Level 1 up to
Level 4 (see Diesel particulate filter clogging sequence – Engine indicator
lamp).