PREVOST X3-45 COACH 2018 Operator's Manual page 146

Table of Contents

Advertisement

6-4
Starting and Stopping Procedures
cables
be
used
correctly
emergencies. To jump start, use another 24 volt
DC, negative grounded, power source. Use only
jumper cables rated at 500 cranking amperes.
DANGER
Injury, explosion, battery acid damage or
charging system overload may result if these
jump starting procedures are not precisely
followed.
WARNING
Wear eye protection and remove rings, metal
jewelry and watches with metal bands.
DANGER
The gases given off by batteries while jump
starting are explosive.
batteries.
DANGER
The battery could rupture or explode if jump
started when the run-down battery fluid is
frozen or if the battery fluid level is low. Check
condition
of
run-down
attempting to jump start.
CAUTION
Do not let the two vehicles touch. Keep a
walk-through
distance
vehicles. Make sure positive (red) and
negative (black) jumper cable clamps do not
touch.
CAUTION
Never connect the jumper cable to the
negative terminal post of the run-down battery.
WARNING
Before attempting to jump start, make sure the
parking brake is applied and the transmission
is in neutral (N). Turn off all lights, heaters
and other electrical accessories.
CAUTION
and
only
in
Do not smoke near
battery
before
between
the
two
PA1627 X3-45 Operator's Manual
Choose a booster vehicle which produces
comparable amperage as your vehicle.
To jump start, proceed as follows:
1. Remove the protective cap from the booster
block terminal located in the R.H. side
engine compartment;
2. Connect one end of the red jumper cable to
the positive (+) post of the booster power
source.
If the good battery is in another
vehicle, that vehicle's engine must be shut
OFF before connecting;
3. Connect the other end of the same red
jumper cable to the positive (+) terminal on
the booster block;
4. Connect one end of the black jumper cable
to the negative (-) post on the booster power
source;
5. Connect the other end of the same black
jumper cable to the negative (-) terminal on
the booster block; If the good battery is in
another vehicle, start that vehicle's engine;
BOOSTER BLOCK LOCATION
6. Let the engine run for a few minutes, then
start the vehicle with the run-down battery;
7. Disconnect the jumper cables in reverse
order given in steps 2 through 5;
8. Install protective cap on the booster block
terminal.
NOTE
Jumper cables must be rated at 500 cranking
amperes. If jumper cable length is 20 feet (6
m) or less, use 2/0 (AWG) gauge wires. If
cable length is between 20 to 30 feet (6 to 9
m), use 3/0 (AWG) gauge wires.
06623

Advertisement

Table of Contents
loading

This manual is also suitable for:

X3-45 2017X3-45 2018

Table of Contents