FR (Software Reset) command

AT Command: ATFR
Minimum Firmware Version Required: v1.x80
<Special> The FR command is used to force a software reset on the RF module. The reset simulates
powering off and then on again the module.

GT (Guard Times) command

AT Command: ATGT
Parameter Range:2 - 0x0CE4
Default Parameter Value:0x3E8
Related Command: CC (Command Sequence Character)
<AT Command Mode Options> GT Command is used to set the DI (data in from host) time-of-silence
that surrounds the AT command sequence character (CC Command) of the AT Command Mode
sequence (GT + CC + GT).
The DI time-of-silence is used to prevent inadvertent entrance into AT Command Mode.
Refer to the Command Mode section for more information regarding the AT Command Mode
Sequence.

HV (Hardware Version) command

AT Command: ATHV
Parameter Range:0 - 0xFFFF [Read-only]
Minimum Firmware Version Required: v1.x80
<Diagnostics> The HV command is used to read the hardware version of the RF module.

IA (I/O Input Address) command

AT Command: ATIA
Parameter Range:0 - 0xFFFFFFFFFFFFFFFF
Default Parameter Value:0xFFFFFFFFFFFFFFFF
(will not allow any received I/O packet to change outputs)
Minimum Firmware Version Required: v1.xA0
<I/O Settings {I/O Line Passing}> The IA command is used to bind a module output to a specific
address. Outputs will only change if received from this address. The IA command can be used to set/
read both 16 and 64-bit addresses.
XBee / XBee-PRO RF Modules 802.15.4 Product Manual
[x 1 millisecond]
(1000 decimal)
Command descriptions for the XBee/XBee-PRO RF Module
72