D5 (Dio5 Configuration) Command; D6 (Dio6 Configuration) Command - Digi XBee Product Manual

Hide thumbs Also See for XBee:
Table of Contents

Advertisement

D5 (DIO5 Configuration) command

AT Command: ATD5
Parameter Range:0 - 5
Parameter
0
1
2
3
4
5
Default Parameter Value:1
Parameters 2-5 supported as of firmware version 1.xA0
<I/O Settings> The D5 command is used to select/read the behavior of the DIO5 line (pin 15).
Options include:
Associated Indicator (LED blinks when the module is associated)
Analog-to-digital converter
Digital input
Digital output

D6 (DIO6 Configuration) command

AT Command: ATD6
Parameter Range:0 - 5
Parameter
0
1
2
3
4
5
Default Parameter Value:0
Parameters 3-5 supported as of firmware version 1.xA0
XBee / XBee-PRO RF Modules 802.15.4 Product Manual
Command descriptions for the XBee/XBee-PRO RF Module
Configuration
Disabled
Associated Indicator
ADC
DI
DO low
DO high
Configuration
Disabled
RTS Flow Control
n/a
DI
DO low
DO high
66

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xbee-pro rf

Table of Contents