Mecmesin MultiTest-x Manual
The required power supply voltage (110-120V or 220-240V) is indicated by the
marker on the panel (3) within the fuse cartridge housing. Your local Mecmesin
representative will already have checked that the fuse cartridge has been installed
correctly for the supply voltage in your country. It is possible to modify your
MultiTest-x for operation in a country with a different supply voltage by: turning off
the power, removing the fuse cartridge housing, checking that both fuses are fitted,
rotating the cartridge through 180º, then reassembling and reinstalling. (The marker
will now point to the new voltage rating on the cartridge panel (3).)
Communication with external equipment is via two ports on the back panel.
The nine-pin D-connector (4) is for RS232 communication with external devices
using the serial cable supplied. Choosing the 'Print Menu' option from the Main
Menu gives more information about configuring RS232 communication, and
downloading data to other equipment, e.g. PCs and dataloggers. The MultiTest-x
firmware can also be upgraded via this port by your agent.
The fifteen-pin D-connector (5) is for further digital input/output communication,
e.g. with PLC equipment; more information and an appropriate cable can be
obtained from your local Mecmesin distributor.