The Pump Surface Temperature Is Above 100 °C; The Vacuum Is Not Fully Maintained After The Pump Is Switched Off; The Pumping Speed Is Poor; There Is An External Oil Leak - Edwards RV3 Instruction Manual

Rotary vane pumps
Hide thumbs Also See for RV3:
Table of Contents

Advertisement

7.5 The pump surface temperature is above 100 °C
Note:
If the inlet pressure is continuously higher than 100 mbar (1 x 10
temperature of the RV12 pump can reach 115 °C when the ambient temperature is 40 °C.
The ambient temperature is too high.
The cooling-air supply is insufficient or is too hot.
The electrical supply voltage is too high.
The outlet-filter or the outlet pipeline is blocked.
The oil-level is below minimum level.
The pump has been filled with the wrong type of oil.
The oil is contaminated.
The process gas is too hot or the throughput is too high.

7.6 The vacuum is not fully maintained after the pump is switched off

The gas-ballast control is open (in position 'I' or 'II').
The inlet valve-pad is damaged.
The inlet valve has not closed.

7.7 The pumping speed is poor

The connecting pipelines are too small in diameter.
The connecting pipelines are too long.
The inlet-filter is blocked.

7.8 There is an external oil leak

The outer shaft-seal is worn or damaged.
The oil-box gaskets have deteriorated.
There is an oil leak from the gas-ballast control.
There is an oil leak from the drain-plug.
There is an oil leak from the sight-glass.
A65201880_AA
A65201880_AA - Fault finding
Page 48
4
Pa), the surface
03/2021 - ©Edwards Limited

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rv5Rv8Rv12

Table of Contents