- for Zone 2 / 22
In the DC variant The POLARIS PROFESSIONAL Panel PC series is protected internally
by a 4 A time-lag fuse and in the AC variant it is protected by a 1.6 A time-lag fuse.The fuse
may be triggered in the case of voltage dips or undervoltage.
Internal fuse
Little fuse
1500A@250VAC
1.6 A T
Little fuse
1500A@250VAC
2.5 A T
We recommend protecting the POLARIS with an upstream fuse to prevent blowing the
fuse inside the device. Only BARTEC can change the internal fuse.
Upstream fuse for
AC: 1.6 A quick-acting (since June 2015: 2.5 A)
DC: 4 A quick-acting.
The I
value must be taken into consideration for other versions of fuses.
2
Certain basic measures must be taken to ensure freedom from interference when the
POLARIS are installed:
- The interference voltages coupled into the device via power, data and signal line and
the electrostatic voltage caused by contact are to be dissipated through the equipotential
bonding.
- The installation point should be as far as possible away from fields of electromagnetic
interference. This is especially important if there are frequency converters in the vicinity.
Under certain circumstances will it be advisable to set up partitions to isolate the graphic
display from interference.
- If inductive devices are fitted in the vicinity (e.g. contactor, relay or solenoid coils),
especially if they are powered from the same source, protective circuits (e.g.
RC elements) must be installed.
- Power supply and data cables must be laid so as to avoid interference. This can be
achieved, for example, by avoiding laying such cables in close proximity to high-current
carrying cables.
I2 value
External fuse
Siba 1.6 A F
6.83 A
s
Siba 2.0 A F
2
Siba 2.5 A F
Eska 1.6 A M
22.29
Eska 2 A M
Installation
1500A@250VAC
1500A@250VAC
1500A@250VAC
1000A@250VAC
1000A@250VAC
43/66