POLARIS PROFESSIONAL
POLARIS Panel PC Professional 15" up to 24"
5.6.5
RS485 interface
Technical data subject to change without notice.
08/2019
- for Zone 2 / 22
Setting of the terminal resistors at the start and end of the bus line is not necessary in
most cases due to internal EMC measures. Depending on local circumstances, the data
transmission may worsen in individual cases.
The appropriate pin assignment of the controller can be found in the manufacturer's
interface description.
Under Os Windows 7 or 10 is only a point to point connection possible.
Configuration RS485
Klemme Schnittstelle
X17
N.C.
X18
N.C.
X19
Interface COM 1
X20
Interface COM 1
X21
N.C.
X22
N.C.
X23
N.C.
X24
N.C.
X25
Interface COM 1
X26
Interface COM 1
Connection PLC with RS485 to POLARIS
Maximum length of the data line 1,000 m
The appropriate pin assignment of the controller can be found in the manufacturer's
interface description.
Signal
Bemerkungen
TxD B (TxD+)
to PLC
TxD A (TxD-)
RxD B (RxD+)
to next POLARIS
RxD A (RxD-)
Installation
33/66