Panel pc professional 10.4" / 12.1" / 12.1" w (73 pages)
Summary of Contents for Bartec POLARIS II PROFESSIONAL
Page 1
Reservation: Technical data subject to change without notice. Changes, errors and misprints may not be used as a basis for any claim for damages. Contents Page English 1 - 52 GmbH Max-Eyth-Straße 16 Phone: +49 7931 597-0 Contact: 97980 Bad Mergentheim Fax: +49 7931 597-119 support-polaris@bartec.de Germany...
POLARIS PROFESSIONAL Table of Contents POLARIS II Panel PC Basic Safety Instructions........................1 Notes on this manual ....................1 Languages ........................2 Changes to the document ................... 2 Handling the product ....................2 Use in accordance with the intended purpose ............2 1.3.1 Exclusive purpose ...................
Page 4
Operating system ...................... 31 8.1.1 Windows 10 IOT .................... 31 8.1.2 Windows 7 Ultimate ..................32 Onboard Bartec Recovery Solution ................32 8.2.1 Bartec Recovery Solution ................32 8.2.2 Start of the device in the Recovery mode ............32 8.2.3 Recovery surroundings .................. 33 8.2.4 4.
Page 5
POLARIS PROFESSIONAL Inhalt POLARIS II Panel PC Additional Information ........................45 EU Declaration of Conformity ......................46 Technical data subject to change without notice. Issue: April 2011...
They are not necessarily true to scale and may deviate s from the actual construction of the device. The BARTEC company reserves the right to carry out technical changes at any tim In no event will BARTEC company be responsible or liable for indirect or conseq damages resulting from the use or application of this user manual.
In case of doubt, the German safety instructions shall apply because it is not possible to rule out errors in translation or in printing. In the event of a legal dispute, the “General Terms and Conditions” of the BARTEC group shall apply in addition.
POLARIS PROFESSIONAL Basic POLARIS II Panel PC Safety Instructions 1.3.3 Owner’s/Managing Operator’s Obligations The owner/managing operator undertakes to restrict permission to work with the POLARIS to people who: are familiar with the basic regulations on safety and accident prevention and have ...
Basic POLARIS PROFESSIONAL Safety Instructions POLARIS II Panel PC 1.5.3 Inspection Under IEC 60079-19 and EN 60079-17, the owner/managing operator of electrical installations in hazardous areas is obliged to have these installations checked by a qualified electrician to ensure that they are in a proper condition. 1.5.4 Repairs Under EN/IEC 60079-17 and EN/IEC 60079-19, the owner/managing operator of electrical...
We guarantee the POLARIS and its accessories for a period of 1 year starting from the BARTEC delivery date. This guarantee covers all parts of the delivery and is restricted to the replacement free of charge or the repair of the defective parts in our Bad Mergentheim factory.
POLARIS PROFESSIONAL Product Description POLARIS II Panel PC Product Description Definition The POLARIS II Panel PCs are based on a fast Intel® TM Celeron® CPU. The Ethernet interface enables individual computers or network devices such as for example a printer to be connected to an existing local network (LAN) (optionally through WLAN also) or local networks to be set up completely wirelessly.
POLARIS PROFESSIONAL Product Description POLARIS II Panel PC Schematic design 2.2.1 PLC connection Illustration 2: Example for possible connection 2.2.2 Connection with Bluetooth Scanner 2.2.3 HMI with mobile process monitoring (separate WLAN network) Technical data subject to change without notice. 7/45 12/2018...
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC Explosion protection and approvals Explosion protection POLARIS II Panel PC Typ 17-72V4-**** ATEX II 3G Ex nA ic IIC T5 Gc Ex protection II3(2)G (1)G Ex nA ic [ic] [ib Gb) [op is Ga] IIC T4/5 Gc (maximum marking) II 2D Ex ib tb IIIC T100°C Db -20 °C ≤...
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC Technical Data General data Stainless steel enclosure Construction Intel® Celeron® J1900 Computer capacity (quad-core up to 2.42.GHz) 4 GB RAM bei 32 Bit OS 8 GB RAM bei 64 Bit OS SSD 128 GByte (MLC-Type) Hard drive Windows 7®...
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC 4.1.1 Characteristics POLARIS II Panel PC Professional PC 19,1" Display 19.1" graphics-capable TFT display SXGA resolution 1.280 x 1.024 pixels 16.7 million colours Brightness 300 cd/m Visible surface approx. 376 x 301 mm Contrast1300:1 Backlight LED technology, Service life...
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC 4.1.3 Characteristics POLARIS II Panel PC Professional PC 24" Display 24" graphics-capable TFT display Full HD resolution 1.920 x 1.080 pixels 16.7 million colours Brightness 300 cd/m Visible surface approx. 531 x 299 mm Contrast 5000:1 Backlight LED technology, Service life...
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC 4.1.5 USB Smart Device 4.1.5.1 Explosion Type 17-71VZ-A0x0/0000 Ex protection type ATEX II 2G Ex eb mb IIC T4 Gb II 2D Ex tb IIIC T120 °C Db Certification IBExU 05 ATEX 1117 X Technical Data Fastening M30 x 1,5 (suitable for fixing holes 30,3mm)
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC 4.1.6 Heating (Optional) for Version up to -20°C Type HCS 40 Ex protection type II 2G Ex db IIC T4 II 2D td IIIC T135°C Product marking Certification PTB 03 ATEX 1139 X Material Black aluminium Power...
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC Product Labeling Type label example Depending on operating system License sticker Technical data subject to change without notice. 14/45 07/2018...
A written report of any transport damage or missing items must be given to the appointed forwarder and to BARTEC GmbH immediately on receipt of the delivery. BARTEC GmbH’s warranty conditions do not cover damage caused by incorrect storage. Required Tools:...
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC Installation We recommend setting up the complete system under laboratory conditions and testing it before it is permanently installed. If a long connection cable is not available, please use a patch cable to test the basic functions. DANGER Electrostatic charging through a stream of particles.
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC Mechanical installation CAUTION This device is heavy (approx .17 kg). Risk of injury if lifted or moved incorrectly. Movable enclosure parts on the swivel-mounted enclosure. There is a risk of injury by hands being crushed. 3 people are required to set up the POLARIS.
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC 6.2.1 Floor mounting Illustration 3: Drilling pattern - supporting system for floor mounting 6.2.2 Wall mounting Illustration 4: Drilling pattern - supporting system for wall mounting Technical data subject to change without notice. 18/45 07/2018...
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC 6.2.3 Table mounting Illustration 5: Drilling pattern - supporting system for table mounting 6.2.4 Rotating/ Inclining Rotating The POLARIS is fixed using two side T screws. The angle of rotation can be changed once the screws have been loosened Inclining The POLARIS is fixed on the carrier system using two hexagon socket screws M10 and a T screw.
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC Electrical Installation 6.3.1 Installation guidelines Only qualified personnel, i.e. trained electricians will have the required specialised knowledge to be able to do all the electrical work. Familiarity with and the technically perfect implementation of the safety instructions described in this manual are preconditions for safe installation and commissioning.
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC 6.3.2 PE conductor connection DANGER Death or danger of injury as a result of no PE conductor connection. There is no explosion protection. Equipotential bonding with a core cross-section of at least 4 mm is to be set up for the POLARIS (see Figure).
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC Junction Box DANGER Non-certified cable glands and non-sealed cable entries endanger the IP protection and accordingly the protection against explosions. There is a risk of fatal injury in an explosive atmosphere! Use Ex-certified cable glands. Close non-sealed cable entries.
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC 6.4.1 POLARIS Junction Box Illustration 8: POLARIS II Panel PC junction box 6.4.2 Terminal assignment X1 Interface AC/DC Signal Description X1-1 Supply Internal protective, protective earth X1-2 Supply L1/+ AC 230 V ± 10 %/ DC 24 V ± 10 % X1-3 Supply Neutral conductor...
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC 6.4.3 Terminal assignment X1 with Heating HCS (optional) Terminal Interface AC/DC Signal Description X1-1 Supply Internal protective, protective earth X1-2 Supply L1/+ AC 230 V ± 10 % or DC 24 V ± 10 % X1-3 Supply Neutral conductor...
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC 6.4.5 Establishing the LAN connection Two RJ45 connectors for customer assembly are enclosed for the connection. Illustration 12: RJ 45-plug For an Ethernet connection, observe the instructions in Chapter 4.5 "EMC". Assembly The plug connector can be used for cables with an external diameter of 4.5...8.0 mm (suitable for LAN STP cables, CAT.7 4x2x23 AWG;...
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC Use a small diagonal cutter to cut the core wires (see illustration). Establish core contact by pressing the terminal (10) blocks together (see fig.) It is also possible to use standard pliers as an aid.
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC EMC (Electromagnetic Compatibility) 6.5.1 Note This is a class A unit and can cause radio interference in residential areas; if it does, the owner/managing operator may be required to implement suitable measures and pay for loss or damage.
PE/PA. 6.5.3 Back-up fuse We recommend protecting the POLARIS with an upstream fuse to prevent blowing the fuse inside the device. Only BARTEC can change the internal fuse. Upstream fuse for AC: 5 AT DC: 5 AT 6.5.4...
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC The plug casing of some controllers is not always well connected to earth. In such cases it may prove advantageous to insulate the shielding from the sub-D plug of the controller and connect it directly to the protective earth conductor by means of a cable that should be kept as short as possible (0.75 mm²...
POLARIS PROFESSIONAL Technical Data POLARIS II Panel PC Commissioning For electrical systems the relevant installation and operating specifications (e.g. Directives 99/92/EC and 94/9/EC, BetrSichV and the applicable national ordinances, IEC 60 079-14 and the DIN VDE 0100 series) must be observed. The operator of an electrical system in a hazardous environment must keep the operating equipment in an orderly condition, operate it correctly, monitor it and do the required maintenance and repairs.
POLARIS PROFESSIONAL Operation POLARIS II Panel PC Operation Once the final inspection has been carried out, the device can be put into operation. The POLARIS series does not have any ON/OFF switch. An external power switch is used to turn the device on and off. Operating system The POLARIS series are fully pre-installed with the Windows®...
The Bartec HMI Polaris Smart devices are equipped with an On-Board-Recovery solution. The Bartec Recovery is a software package preloaded on the devices which serves the disregard of the device in the work state. In case of a mistake every device can be booted up in the Recovery mode to move afterwards the operating system into the work state.
POLARIS PROFESSIONAL Operation POLARIS II Panel PC ATTENTION All data on Windows partition are definitely extinguished during the recovery of process! All self-provided data or use data should be protected from starting the recovery. For the Recovery mode the hard disk contains a hidden partition to the storage of the Recover engine and the image file (effigy of the operating system).
POLARIS PROFESSIONAL Operation POLARIS II Panel PC Illustration 17: CMD window with information 8.2.4 4. Recovery application Should the check be concluded successfully, the Recovery application is begun (besides, the window CMD is automatically closed). Before the restoration of the device in the work state must be agreed Microsoft software Licence terms interactively.
POLARIS PROFESSIONAL Operation POLARIS II Panel PC All other pictures in the instructions refer to Recovery of Windows 10 IoT Enterprise of operating system. In case of the restoration of Windows 7 Embedded Ultimate or standard of operating system the pictures look similar. Besides, all background expiries are identical, with the differences it is only about inscriptions.
Page 44
POLARIS PROFESSIONAL Operation POLARIS II Panel PC In the upper area of the window the inscription of the well-chosen function is indicated. In the next line – the inscription of the already running background process. Should a process be computable, the proportional issue appears in the next line how far the process is already concluded.
POLARIS PROFESSIONAL Operation POLARIS II Panel PC Illustration 21: Prepare the partition After preparing the partition all files from the effigy image stored on the Recovery partition are unpacked and transferred on the operating system partition. Illustration 22: Transferred by system files on operating system partition Transferring of system files is the last process with the Widerherstellung of the operating system in the work state.
The POLARIS can be restored to delivery status by means of a recovery stick. The recovery flash drive is not included in the scope of supply. It can be ordered from the contact address www.bartec.de The recovery flash drive contains the functions: image recovery (factory reset) ...
Calibration of Touch Screen In the POLARIS with touch screen, the touch screen software is pre-installed already. The touch screen software is available for download under http://www.bartec.de/automation-download/ 8.4.1 Calibration of Touch Screen The calibration of the touch screen must be carried out with the corresponding touch tool.
POLARIS PROFESSIONAL Troubleshooting POLARIS II Panel PC Troubleshooting No image Check voltage connection. No network recognised Check Ethernet connection to the POLARIS. Check connection cable to the network; it might not be connected. No remote access Check the host computer’s IP address. ...
POLARIS PROFESSIONAL Maintenance, Inspection POLARIS II Panel PC Repair Maintenance, Inspection, Repair Only trained and qualified personnel may commission and do maintenance work on the POLARIS! Trained qualified personnel are people who are familiar with the installation, assembly, commissioning and operation of the POLARIS, have been instructed about the risks and have the appropriate qualifications by virtue of the work they do.
If you wish to send in a defective device for repair, please read the RMA procedure guidance first. Then fill in and sign the RMA (Return Merchandise Authorisation) form and send it to our "Retouren Center". E-mail: services@bartec.de Fax: +49 7931 597-119 We cannot guarantee any contractually agreed processing times for devices that are sent in without an RMA number.
On request Keyboard with integrated Touchpad On request Smart USB Device Bluetooth 17-71VZ-A020/0000 W-LAN 17-71VZ-A010/0000 BARTEC Recovery Stick Windows 10 Iot On request Windows 7 Ultimate On request Tragarmsystem Stand for floor mounting 05-0005-0078 Material: Stainless steel DIN 1.4301, Rotatable Height approx.
POLARIS PROFESSIONAL Order Numbers POLARIS II Panel PC Order Numbers Version 19,1“ Version 22“ Version 24“ Technical data subject to change without notice. 44/45 12/2018...
Page 53
POLARIS PROFESSIONAL Additional Information POLARIS II Panel PC Additional Information Technical data subject to change without notice. 45/45 12/2018...